KAIYUE KAIYUEGENERATOR PARTS
Get a Quote
KAIYUE / PROFESSIONAL PRODUCTS

Leroy Somer AVR Series.
Find your next part.

Leroy Somer AVR Series regulators control alternator voltage by adjusting exciter field current from sensed output. The excitation supply can vary with the alternator and regulator version. During service, inspect sensing and field connections, then confirm the board suffix and excitation arrangement against the alternator documentation.

12PRODUCTS TO EXPLORE

Leroy Somer AVR Series

12 products

Generator Automatic Voltage Regulator Leroy Somer  AVR R120
Generator AVR

R120

Generator Automatic Voltage Regulator Leroy Somer AVR R120

Generator Automatic Voltage Regulator Leroy Somer  AVR R150
Generator AVR

R150

Generator Automatic Voltage Regulator Leroy Somer AVR R150

Generator Automatic Voltage Regulator Leroy Somer  AVR R220
Generator AVR

R220

Generator Automatic Voltage Regulator Leroy Somer AVR R220

Generator Automatic Voltage Regulator Leroy Somer AVR EM10
Generator AVR

EM10

Generator Automatic Voltage Regulator Leroy Somer AVR EM10

Generator Automatic Voltage Regulator Leroy Somer AVR R230
Generator AVR

R230

Generator Automatic Voltage Regulator Leroy Somer AVR R230

Generator Automatic Voltage Regulator Leroy Somer AVR R250
Generator AVR

R250

Generator Automatic Voltage Regulator Leroy Somer AVR R250

Generator Automatic Voltage Regulator Leroy Somer AVR R438
Generator AVR

R438

Generator Automatic Voltage Regulator Leroy Somer AVR R438

Generator Automatic Voltage Regulator Leroy Somer AVR R448
Generator AVR

R448

Generator Automatic Voltage Regulator Leroy Somer AVR R448

Generator Automatic Voltage Regulator Leroy Somer AVR R449
Generator AVR

R449

Generator Automatic Voltage Regulator Leroy Somer AVR R449

Generator Automatic Voltage Regulator Leroy Somer AVR R450
Generator AVR

R450

Generator Automatic Voltage Regulator Leroy Somer AVR R450

Leroy Somer AVR Series Technical Guide

Product features

Leroy Somer AVR Series boards are identified by their full model and suffix. Match them to the alternator and its excitation arrangement before comparing settings or wiring.

How it works

By monitoring output and controlling exciter field current, the AVR holds the target voltage. Different excitation arrangements use different power feeds to the board.

Troubleshooting

If voltage will not build, inspect sensing and excitation feeds as separate circuits. Check model-specific fuses or protection indications where provided.

Replacement options

The series includes several R-series references. Use the suffix, terminal layout and alternator documentation to identify the appropriate replacement.

How to replace it

Isolate the alternator and label terminal functions before removal. Use the specific Leroy Somer documentation to restore wiring and confirm voltage performance under load.

PRODUCT GUIDANCE

Frequently asked questions

Leroy Somer AVR Series guidance for selection, use and purchasing.

Explore more FAQs ↗
Which alternators use Leroy Somer regulators?

They are associated with Leroy Somer alternators and compatible excitation systems. Exact model matching must be confirmed — confirm the specification with our team.

View this answer in FAQs ↗
How do I identify the correct regulator for my alternator?

Use the alternator nameplate together with the existing regulator reference, since one alternator family can use several regulator variants — confirm the specification with our team.

View this answer in FAQs ↗
Is a listed regulator original or equivalent?

KAIYUE is the product brand of Fujian Kaiyue Electronics Co.,Ltd. Brand-series references help identify the intended application. Confirm the product origin, supplied configuration and suitability for the exact reference with our team before ordering.

View this answer in FAQs ↗
What causes voltage instability on these alternators?

Instability can originate from regulator settings, sensing wiring, engine speed variation, or excitation component wear. Confirm frequency stability and sensing integrity first.

View this answer in FAQs ↗
Does the regulator need configuration after installation?

Many regulators require voltage and stability setting, and some provide additional configuration options. Follow the documentation for the specific model — confirm the specification with our team.

View this answer in FAQs ↗
Can I use a different brand regulator on a Leroy Somer alternator?

Cross-brand substitution is sometimes technically possible but must be validated against excitation and sensing requirements — confirm the specification with our team.

View this answer in FAQs ↗
What should I check before replacing an AVR under warranty?

Record the fault symptoms, measured voltages, frequency and excitation readings, and confirm wiring integrity. This documentation supports the warranty assessment.

View this answer in FAQs ↗
Why does the generator overvoltage on start-up?

Overvoltage at start-up may indicate a wiring or sensing error, an incorrect regulator model or an incorrect voltage setting. Stop the set and verify configuration before repeating the start.

View this answer in FAQs ↗
Are these regulators sensitive to harmonic loads?

Non-linear loads can affect sensing accuracy and regulation behaviour depending on the design. Confirm suitability for your load type — confirm the specification with our team.

View this answer in FAQs ↗
What information should accompany an enquiry?

Include alternator model and serial data, regulator reference, rated voltage and frequency, application details, quantity and nameplate photos. ---

View this answer in FAQs ↗

Guidance varies by model and installation. Confirm specifications and suitability for your selected part with our team.

Not sure which part you need?

Send a model number, reference photo or application details to our team.

Ask KAIYUE ↗

KAIYUE / REQUEST A QUOTE

20 YEARS EXPERIENCE FOR GENSET PARTS


Email is required so we can reply to your inquiry.