A generator controller coordinates starting, running, monitoring and shutdown. It reads engine and electrical signals, then operates outputs for functions such as cranking and fuel control. At routine service, review the alarm log and inspect input wiring. Confirm start mode and sensor compatibility before replacing the module.

50PRODUCTS TO EXPLORE

Generator Controller

50 products

Comap Controller Auto Mains Failure AMF Generator Controller AMF20
Comap Controller Series

AMF20

Comap Controller Auto Mains Failure AMF Generator Controller AMF20

Comap Controller Auto Mains Failure AMF Generator Controller AMF25
Comap Controller Series

AMF25

Comap Controller Auto Mains Failure AMF Generator Controller AMF25

Comap Controller Auto Mains Failure AMF Generator Controller AMF9
Comap Controller Series

AMF9

Comap Controller Auto Mains Failure AMF Generator Controller AMF9

Comap Controller Manual Remote Start(MRS) Generator Controller MRS10
Comap Controller Series

MRS10

Comap Controller Manual Remote Start(MRS) Generator Controller MRS10

Comap Controller Manual Remote Start(MRS) Generator Controller MRS11
Comap Controller Series

MRS11

Comap Controller Manual Remote Start(MRS) Generator Controller MRS11

Comap Controller Manual Remote Start(MRS) Generator Controller MRS16
Comap Controller Series

MRS16

Comap Controller Manual Remote Start(MRS) Generator Controller MRS16

Datacom Controller Auto Mains Failure AMF Generator Controller DKG105
Datakom Controller Series

DKG105

Datacom Controller Auto Mains Failure AMF Generator Controller DKG105

Datacom Controller Auto Mains Failure AMF Generator Controller DKG155
Datakom Controller Series

DKG155

Datacom Controller Auto Mains Failure AMF Generator Controller DKG155

Datacom Controller Auto Mains Failure AMF Generator Controller DKG300
Datakom Controller Series

DKG300

Datacom Controller Auto Mains Failure AMF Generator Controller DKG300

Datacom Controller Auto Mains Failure AMF Generator Controller DKG307
Datakom Controller Series

DKG307

Datacom Controller Auto Mains Failure AMF Generator Controller DKG307

Datacom Controller Auto Mains Failure AMF Generator Controller DKG309
Datakom Controller Series

DKG309

Datacom Controller Auto Mains Failure AMF Generator Controller DKG309

Datacom Controller Auto Mains Failure AMF Generator Controller DKG500
Datakom Controller Series

DKG500

Datacom Controller Auto Mains Failure AMF Generator Controller DKG500

Generator Controller Technical Guide

Product features

Generator controllers range from remote-start modules to automatic mains failure and paralleling controllers. Confirm the application, sensor inputs, DC supply and required control outputs.

How it works

The module applies start and stop timers, reads running feedback and monitors protection inputs. AMF models also evaluate the mains supply and can coordinate transfer with the panel.

Troubleshooting

For a failed start, read the alarm history and check DC supply and start permissions. Separate a missing crank output from a starter, fuel circuit or speed feedback problem.

Replacement options

Compare modules by application and hardware version, then match wiring and configuration. Similar front panels can hide different input and output assignments.

How to replace it

Disable automatic start and save the existing configuration where supported. Label connectors, use the model wiring guide and verify manual, remote or auto start plus shutdown logic as applicable.

PRODUCT GUIDANCE

Frequently asked questions

Generator Controller guidance for selection, use and purchasing.

Explore more FAQs ↗
What does a generator controller do?

It manages starting, stopping, monitoring and protection for the generator set. It reads engine and alternator signals, displays status and trips the set on fault conditions.

View this answer in FAQs ↗
How do AMF and manual or remote-start controllers differ?

AMF controllers can detect a mains failure and manage a configured start and transfer sequence. Manual or remote-start controllers may accept a local command or a configured remote input. Available functions depend on the model, wiring and operating mode.

View this answer in FAQs ↗
How do I choose the right controller for my generator?

Selection depends on required functions, display type, sensor inputs, output contacts, communication protocols and whether AMF or paralleling is needed. Confirm the feature list against your application — confirm the specification with our team.

View this answer in FAQs ↗
Can I replace an old controller with a newer model?

Replacement is often possible but may require wiring changes, new sensors and reconfiguration. Compatibility must be reviewed per model — confirm the specification with our team.

View this answer in FAQs ↗
Why does the controller show a shutdown alarm during starting?

Starting-phase alarms often relate to low oil pressure signals, overcrank, failed speed sensing or incorrect configuration. Review the fault log and sensor wiring.

View this answer in FAQs ↗
Does the controller need programming after installation?

Most controllers require configuration of engine parameters, protection thresholds, timers and input/output functions. Configuration should follow the engine and alternator ratings.

View this answer in FAQs ↗
Can the controller communicate with a building management system?

Many controllers provide serial or network communication options. Confirm the available protocols for your model — confirm the specification with our team.

View this answer in FAQs ↗
What causes false overspeed trips?

False overspeed can come from speed sensor gap errors, electrical noise, incorrect flywheel tooth settings or a damaged sensor cable. Inspect the sensor installation and wiring routing.

View this answer in FAQs ↗
How do I back up controller settings?

Some controllers support configuration export via software or memory tools. Confirm whether your model supports backup — confirm the specification with our team.

View this answer in FAQs ↗
What details are needed for controller selection?

Provide generator rating, voltage and frequency, engine type, required functions (AMF, paralleling, communications), sensor types and panel space constraints. ---

View this answer in FAQs ↗

Guidance varies by model and installation. Confirm specifications and suitability for your selected part with our team.

Not sure which part you need?

Send a model number, reference photo or application details to our team.

Ask KAIYUE ↗

KAIYUE / REQUEST A QUOTE

20 YEARS EXPERIENCE FOR GENSET PARTS


Email is required so we can reply to your inquiry.

en_US
en_US