DSE8610 MKII
Deep Sea Controller Auto Start Control Module DSE8610 MKII for generator
Deep Sea Controller Auto Start Control Module DSE6010 for generator
DSE6010 Deep Sea genset auto-start module.
| Warranty | 13 months |
|---|---|
| Place of Origin | Fujian, China |
| Brand Name | KAIYUE |
| Model Number | DSE6010 |
| OVERALL SIZE | 216 x 158 x 43 mm |
| PANEL CUTOUT SIZE | 184 x 137 mm |
| Certification | CE,ISO9001 |
| Parameter | Original | KAIYUE Replacement |
|---|---|---|
| Control type | AMF / MRS / Auto-Start | Auto-Start with genset protection |
| DC supply | 12/24 VDC nominal | 12/24 VDC selectable; confirm battery system |
| AC sensing | 0–600 VAC, 1/3 phase | 0–600 VAC sensing; terminal map supplied |
| Output rating | Relay outputs, reference-dependent | Relay outputs sized for stated contactor/solenoid loads |
| Magnetic pickup input | 0.5–35 VAC, 10–10,000 Hz | 0.5–35 VAC compatible pickup input |
| Panel cut-out / dimensions | Reference drawing required | Proposed drawing confirmed before shipment |
| Weight / protection | Reference unit; IP rating by enclosure | Approx. 0.72 kg; front sealing option by project |
For the DSE6010 MKII version, two clearly identified market offers ranged from US$381.54 to US$434.00 per controller. The narrow sample provides a preliminary budgeting band, without enough evidence to judge a wider supplier-price trend. Before using it for a replacement-panel order, confirm that the installed module is MKII and compare the connector schedule and configuration requirements. Other DSE6010 generations and DSE6110 modules are outside this version-specific benchmark.
Identify the installed model and compare terminal layout, functions and panel cut-out with the proposed replacement — confirm the specification with our team.
View this answer in FAQs ↗Some replacements are near drop-in while others require wiring and configuration changes. Confirm compatibility for the specific pair of models — confirm the specification with our team.
View this answer in FAQs ↗They are widely used for generator set control, including manual, automatic and AMF operation, with protection and monitoring functions — confirm the specification with our team.
View this answer in FAQs ↗Overcrank indicates the engine did not start within the configured crank attempts. Check fuel supply, starting system, speed sensing and crank timing settings.
View this answer in FAQs ↗Provide generator rating, engine type, required features, communication needs, panel space and photos of the existing installation. ---