DSE520K
Deep Sea Controller Auto Start Control Module DSE520K for generator
DSE520K Deep Sea legacy auto-start controller.
Technical Data
| Warranty | 13 months |
|---|---|
| Place of Origin | Fujian, China |
| Brand Name | KAIYUE |
| Model Number | DSE520K |
| OVERALL SIZE | 72 x 144 x 118.5 mm |
| PANEL CUTOUT SIZE | 65.5 x 111 mm |
| Certification | CE,ISO9001 |
| Parameter | Original | KAIYUE Replacement |
|---|---|---|
| Control type | AMF / MRS / Auto-Start | Auto-Start with genset protection |
| DC supply | 12/24 VDC nominal | 12/24 VDC selectable; confirm battery system |
| AC sensing | 0–600 VAC, 1/3 phase | 0–600 VAC sensing; terminal map supplied |
| Output rating | Relay outputs, reference-dependent | Relay outputs sized for stated contactor/solenoid loads |
| Magnetic pickup input | 0.5–35 VAC, 10–10,000 Hz | 0.5–35 VAC compatible pickup input |
| Panel cut-out / dimensions | Reference drawing required | Proposed drawing confirmed before shipment |
| Weight / protection | Reference unit; IP rating by enclosure | Approx. 0.82 kg; front sealing option by project |
DSE520K Introduction
Global Market Price Reference (USD)
Observed DSE520K replacement auto-start controllers were priced between US$163.00 and US$179.99 per module. The four comparable offers fell within a narrow band, so delivery and fit may matter more than unit price. Require the terminal diagram and panel cutout dimensions with each quote for retrofit stock.
Product FAQs
Explore more FAQs ↗How do I find a direct replacement for an existing unit?+
Identify the installed model and compare terminal layout, functions and panel cut-out with the proposed replacement — confirm the specification with our team.
View this answer in FAQs ↗Can newer models replace older ones directly?+
Some replacements are near drop-in while others require wiring and configuration changes. Confirm compatibility for the specific pair of models — confirm the specification with our team.
View this answer in FAQs ↗What are Deep Sea controllers used for?+
They are widely used for generator set control, including manual, automatic and AMF operation, with protection and monitoring functions — confirm the specification with our team.
View this answer in FAQs ↗Why does the controller show an overcrank fault?+
Overcrank indicates the engine did not start within the configured crank attempts. Check fuel supply, starting system, speed sensing and crank timing settings.
View this answer in FAQs ↗What information helps select the right controller?+
Provide generator rating, engine type, required features, communication needs, panel space and photos of the existing installation. ---
View this answer in FAQs ↗