DSE7320 MKII
Deep Sea Controller Auto Start Control Module DSE7320 MKII for generator
Deep Sea Controller Auto Start Control Module 6110 for generator
DSE6110 Deep Sea single-genset auto-start reference.
| Warranty | 13 months |
|---|---|
| Place of Origin | Fujian, China |
| Brand Name | KAIYUE |
| Model Number | 6110 |
| OVERALL SIZE | 216 x 158 x 43 mm |
| PANEL CUTOUT SIZE | 184 x 137 mm |
| Certification | CE,ISO9001 |
| Parameter | Original | KAIYUE Replacement |
|---|---|---|
| Control type | AMF / MRS / Auto-Start | AMF mains-failure and remote start |
| DC supply | 12/24 VDC nominal | 12/24 VDC selectable; confirm battery system |
| AC sensing | 0–600 VAC, 1/3 phase | 0–600 VAC sensing; terminal map supplied |
| Output rating | Relay outputs, reference-dependent | Relay outputs sized for stated contactor/solenoid loads |
| Magnetic pickup input | 0.5–35 VAC, 10–10,000 Hz | 0.5–35 VAC compatible pickup input |
| Panel cut-out / dimensions | Reference drawing required | Proposed drawing confirmed before shipment |
| Weight / protection | Reference unit; IP rating by enclosure | Approx. 0.38 kg; front sealing option by project |
For offers explicitly identifying DSE6110 without a later-generation suffix, observed prices ranged from US$139.00 to US$191.00 per module. The small matched sample showed a moderate spread, while many other '6110' results belonged to different controller brands or generations. For panel-replacement orders, retain the full DSE reference and confirm the label, connectors and configuration method before comparing batch prices. HGM6110, LXC6110 and MKII variants are excluded.
Identify the installed model and compare terminal layout, functions and panel cut-out with the proposed replacement — confirm the specification with our team.
View this answer in FAQs ↗Some replacements are near drop-in while others require wiring and configuration changes. Confirm compatibility for the specific pair of models — confirm the specification with our team.
View this answer in FAQs ↗They are widely used for generator set control, including manual, automatic and AMF operation, with protection and monitoring functions — confirm the specification with our team.
View this answer in FAQs ↗Overcrank indicates the engine did not start within the configured crank attempts. Check fuel supply, starting system, speed sensing and crank timing settings.
View this answer in FAQs ↗Provide generator rating, engine type, required features, communication needs, panel space and photos of the existing installation. ---
View this answer in FAQs ↗