DSE7220
Deep Sea Controller Auto Start Control Module DSE7220 for generator
Deep Sea Controller Manual Start Control Module DSE501K for generator
DSE501K Deep Sea legacy manual-start control reference.
| Warranty | 13 months |
|---|---|
| Place of Origin | Fujian, China |
| Brand Name | KAIYUE |
| Model Number | DSE501K |
| OVERALL SIZE | 140 x 113 x 43 mm |
| PANEL CUTOUT SIZE | 118 x 92 mm |
| Certification | CE,ISO9001 |
| Parameter | Original | KAIYUE Replacement |
|---|---|---|
| Control type | AMF / MRS / Auto-Start | MRS manual/remote start |
| DC supply | 12/24 VDC nominal | 12/24 VDC selectable; confirm battery system |
| AC sensing | 0–600 VAC, 1/3 phase | 0–600 VAC sensing; terminal map supplied |
| Output rating | Relay outputs, reference-dependent | Relay outputs sized for stated contactor/solenoid loads |
| Magnetic pickup input | 0.5–35 VAC, 10–10,000 Hz | 0.5–35 VAC compatible pickup input |
| Panel cut-out / dimensions | Reference drawing required | Proposed drawing confirmed before shipment |
| Weight / protection | Reference unit; IP rating by enclosure | Approx. 0.41 kg; front sealing option by project |
Identified single-module DSE501K offers ranged from US$34.99 to US$236.64. Replacement-labelled supply also reached the high end, so the spread cannot be explained simply as original versus aftermarket pricing. For manual-start panel projects, compare the key-start arrangement, shutdown inputs and running-feedback requirements, then ask which test records, accessories and warranty services accompany a higher quote. DSE501K-1 versions and quantity-unclear supplier adverts are excluded.
Identify the installed model and compare terminal layout, functions and panel cut-out with the proposed replacement — confirm the specification with our team.
View this answer in FAQs ↗Some replacements are near drop-in while others require wiring and configuration changes. Confirm compatibility for the specific pair of models — confirm the specification with our team.
View this answer in FAQs ↗They are widely used for generator set control, including manual, automatic and AMF operation, with protection and monitoring functions — confirm the specification with our team.
View this answer in FAQs ↗Overcrank indicates the engine did not start within the configured crank attempts. Check fuel supply, starting system, speed sensing and crank timing settings.
View this answer in FAQs ↗Provide generator rating, engine type, required features, communication needs, panel space and photos of the existing installation. ---
View this answer in FAQs ↗