Technical Data
| Warranty | 13 months |
|---|---|
| Place of Origin | Fujian, China |
| Brand Name | KAIYUE |
| Model Number | ESD5500E |
| Working Voltage | 12-32V DC |
| Output Current Range | 0-5A |
| Parameter | Original | KAIYUE Replacement |
|---|---|---|
| Control type | AMF / MRS / Auto-Start | Auto-Start with genset protection |
| DC supply | 12/24 VDC nominal | 12/24 VDC selectable; confirm battery system |
| AC sensing | 0–600 VAC, 1/3 phase | 0–600 VAC sensing; terminal map supplied |
| Output rating | Relay outputs, reference-dependent | Relay outputs sized for stated contactor/solenoid loads |
| Magnetic pickup input | 0.5–35 VAC, 10–10,000 Hz | 0.5–35 VAC compatible pickup input |
| Panel cut-out / dimensions | Reference drawing required | Proposed drawing confirmed before shipment |
| Weight / protection | Reference unit; IP rating by enclosure | Approx. 0.63 kg; front sealing option by project |
| Product Name | GAC Engine Speed Control Unit Speed Controller Droop Governor ESD5500E | |
| Input | Supply | 12 or 24 VDC Battery System (Transient and Reverse Voltage) |
| Polarity | Negative Ground (Case Isolated) | |
| Power Consumption | 50 ma continuous plus actuator current | |
| Actuator Current Range @ 25 Deg. C - (Inductive Load) | Min.2.5 Amps; Max. 10Amps continuous | |
| Vibration | 1G at 20 to 100 Hz. | |
ESD5500E Introduction
Global Market Price Reference (USD)
Two ESD5500E speed governor listings were priced at US$380.00–450.00 per controller. The small sample is a starting point for maintenance budgeting. Base a spares quote on the required actuator and speed pickup, and ask the supplier to state whether bench testing or setup support is included.
Product FAQs
Explore more FAQs ↗How do I choose a replacement governor?+
Selection depends on engine type, mounting, drive arrangement, control signal and required operating mode. Confirm the specification — confirm the specification with our team.
View this answer in FAQs ↗What does a speed governor do?+
It regulates engine fuel delivery to keep speed within the required range as load changes, which maintains generator frequency stability.
View this answer in FAQs ↗Why is the engine hunting at no load?+
No-load hunting usually indicates governor gain or stability settings, worn linkage or fuel system issues. Adjust settings only after mechanical checks.
View this answer in FAQs ↗What information should accompany an enquiry?+
Provide the governor part number, engine make and model, governor type, control signal details, mounting arrangement, quantity and photos. ---
View this answer in FAQs ↗What is the difference between droop and isochronous operation?+
Droop control allows the speed reference to decrease with increasing load and is used in some load-sharing arrangements. Isochronous control aims to maintain the speed setpoint within the system capabilities under steady operating conditions; transient response and parallel load sharing depend on the control design.
View this answer in FAQs ↗