S6700H
GAC Engine Speed Control Unit Speed Controller Droop Governor S6700H
S6700H diesel genset speed governor reference.
Technical Data
| Warranty | 13 months |
|---|---|
| Place of Origin | Fujian, China |
| Brand Name | KAIYUE |
| Model Number | S6700H |
| Working Voltage | 12-32V DC |
| Output Current Range | 0-5A |
| Parameter | Original | KAIYUE Replacement |
|---|---|---|
| Control type | AMF / MRS / Auto-Start | Auto-Start with genset protection |
| DC supply | 12/24 VDC nominal | 12/24 VDC selectable; confirm battery system |
| AC sensing | 0–600 VAC, 1/3 phase | 0–600 VAC sensing; terminal map supplied |
| Output rating | Relay outputs, reference-dependent | Relay outputs sized for stated contactor/solenoid loads |
| Magnetic pickup input | 0.5–35 VAC, 10–10,000 Hz | 0.5–35 VAC compatible pickup input |
| Panel cut-out / dimensions | Reference drawing required | Proposed drawing confirmed before shipment |
| Weight / protection | Reference unit; IP rating by enclosure | Approx. 0.34 kg; front sealing option by project |
|
Product Name |
S6700H Generator Speed Controller |
|
|
Working Voltage |
12V DC 24V DC |
|
|
Output Current Range |
2.5-10A(continuous) |
|
|
Speed Sensor Signal |
0.5-120V RMS |
|
|
Temperature Range |
-40~ +85℃ |
|
|
Ralative Humidity |
<95% |
|
|
Speed Range |
1K-7.5K HZ |
|
|
Speed Trim Range |
+/-200 HZ |
|
S6700H Introduction
Global Market Price Reference (USD)
S6700H replacement-controller offers ranged from US$55.49 to US$1,000.00 per unit. Most sampled quotes were far below the highest compatible listing, so that premium needs a clear explanation in a procurement comparison. Require the H-version terminal diagram, operating-voltage confirmation and functional-test scope with the batch quote, together with lead time and warranty terms.
Product FAQs
Explore more FAQs ↗How do I choose a replacement governor?+
Selection depends on engine type, mounting, drive arrangement, control signal and required operating mode. Confirm the specification — confirm the specification with our team.
View this answer in FAQs ↗What does a speed governor do?+
It regulates engine fuel delivery to keep speed within the required range as load changes, which maintains generator frequency stability.
View this answer in FAQs ↗Why is the engine hunting at no load?+
No-load hunting usually indicates governor gain or stability settings, worn linkage or fuel system issues. Adjust settings only after mechanical checks.
View this answer in FAQs ↗What information should accompany an enquiry?+
Provide the governor part number, engine make and model, governor type, control signal details, mounting arrangement, quantity and photos. ---
View this answer in FAQs ↗What is the difference between droop and isochronous operation?+
Droop control allows the speed reference to decrease with increasing load and is used in some load-sharing arrangements. Isochronous control aims to maintain the speed setpoint within the system capabilities under steady operating conditions; transient response and parallel load sharing depend on the control design.
View this answer in FAQs ↗