
3098693
GAC Engine Speed Control Unit Speed Controller Droop Governor 3098693
3098693 Cummins electronic speed controller reference.
Technical Data
| Warranty | 13 months |
|---|---|
| Place of Origin | Fujian, China |
| Brand Name | KAIYUE |
| Model Number | 3098693 |
| Working Voltage | 24±8V DC |
| Output Current Range | 0-2.5A |
| Parameter | Original | KAIYUE Replacement |
|---|---|---|
| Control type | AMF / MRS / Auto-Start | AMF mains-failure and remote start |
| DC supply | 12/24 VDC nominal | 12/24 VDC selectable; confirm battery system |
| AC sensing | 0–600 VAC, 1/3 phase | 0–600 VAC sensing; terminal map supplied |
| Output rating | Relay outputs, reference-dependent | Relay outputs sized for stated contactor/solenoid loads |
| Magnetic pickup input | 0.5–35 VAC, 10–10,000 Hz | 0.5–35 VAC compatible pickup input |
| Panel cut-out / dimensions | Reference drawing required | Proposed drawing confirmed before shipment |
| Weight / protection | Reference unit; IP rating by enclosure | Approx. 0.48 kg; front sealing option by project |
|
EFC Speed Controller 3098693 For Over 500KW Generator set
|
|
|
Speed stablity |
Better than ±0.25% |
|
Speed range |
1Khz ~ 7.5Khz |
|
Thermostablity |
Max ±1% |
|
Idle adjustment |
160 ± 20Hz ~ Rated speed 95% |
|
Power input |
|
|
Voltage |
12V DC 24V DC |
|
Output |
50mA |
|
Signal of speed sensor |
0.5 ~ 120V RMS |
3098693 Introduction
Global Market Price Reference (USD)
3098693 replacement-controller offers ranged from US$33.65 to US$427.00 per unit. Many listings clustered far below the upper endpoint, so that top quote should be justified by its supply and support terms. For engine-service orders, confirm the installed controller revision and engine application, then compare batch testing and warranty coverage at the same order quantity.
Product FAQs
Explore more FAQs ↗How do I choose a replacement governor?+
Selection depends on engine type, mounting, drive arrangement, control signal and required operating mode. Confirm the specification — confirm the specification with our team.
View this answer in FAQs ↗What does a speed governor do?+
It regulates engine fuel delivery to keep speed within the required range as load changes, which maintains generator frequency stability.
View this answer in FAQs ↗Why is the engine hunting at no load?+
No-load hunting usually indicates governor gain or stability settings, worn linkage or fuel system issues. Adjust settings only after mechanical checks.
View this answer in FAQs ↗What information should accompany an enquiry?+
Provide the governor part number, engine make and model, governor type, control signal details, mounting arrangement, quantity and photos. ---
View this answer in FAQs ↗What is the difference between droop and isochronous operation?+
Droop control allows the speed reference to decrease with increasing load and is used in some load-sharing arrangements. Isochronous control aims to maintain the speed setpoint within the system capabilities under steady operating conditions; transient response and parallel load sharing depend on the control design.
View this answer in FAQs ↗



