DSE702
Deep Sea Controller Manual & Auto Start Control Module DSE702 for generator
SmartGen Controller Auto Start Generator Controller HGM6120U
HGM6120U SmartGen AMF controller with utility monitoring.
| Warranty | 13 months |
|---|---|
| Place of Origin | Fujian, China |
| Brand Name | KAIYUE |
| Model Number | HGM6120U |
| Size | 220 × 175 × 53 mm |
| Weight | 0.8kg |
| Certification | CE,ISO9001 |
| Parameter | Original | KAIYUE Replacement |
|---|---|---|
| Control type | AMF / MRS / Auto-Start | AMF mains-failure and remote start |
| DC supply | 12/24 VDC nominal | 12/24 VDC selectable; confirm battery system |
| AC sensing | 0–600 VAC, 1/3 phase | 0–600 VAC sensing; terminal map supplied |
| Output rating | Relay outputs, reference-dependent | Relay outputs sized for stated contactor/solenoid loads |
| Magnetic pickup input | 0.5–35 VAC, 10–10,000 Hz | 0.5–35 VAC compatible pickup input |
| Panel cut-out / dimensions | Reference drawing required | Proposed drawing confirmed before shipment |
| Weight / protection | Reference unit; IP rating by enclosure | Approx. 0.28 kg; front sealing option by project |
Explicit HGM6120U single-module quotations ranged from US$95.00 to US$241.76. Numerous competing offers sat between the low entry price and the highest quotation, so buyers have room to compare like-for-like supply rather than accept a premium solely for a higher listing price. For AMF-panel orders, make the U suffix, utility-monitoring inputs, relay assignments and configuration support part of the written specification. UC, U2C, CAN, generic 6120U modules, refurbished stock and multi-unit packs were not used for this range.
Replacement is common but requires terminal mapping and reconfiguration. Confirm input/output compatibility — confirm the specification with our team.
View this answer in FAQs ↗Compare measurement capability, protection functions, AMF support, communication interfaces and display options against your requirement — confirm the specification with our team.
View this answer in FAQs ↗They provide generator control, protection and monitoring for standby, prime and AMF applications, with model-dependent features — confirm the specification with our team.
View this answer in FAQs ↗Speed signal loss usually points to a faulty magnetic pickup, incorrect sensor gap, wiring break or configuration mismatch. Inspect the sensor installation.
View this answer in FAQs ↗Include the controller model, generator rating, engine type, required functions, panel dimensions, quantity and photos. ---
View this answer in FAQs ↗