DSE501K
Deep Sea Controller Manual Start Control Module DSE501K for generator
Deep Sea Controller Auto Start Control Module DSE3110 for generator
DSE3110 Deep Sea compact manual and auto-start controller.
| Warranty | 13 months |
|---|---|
| Place of Origin | Fujian, China |
| Brand Name | KAIYUE |
| Model Number | DSE3110 |
| OVERALL SIZE | 98 x 79 x 40 mm |
| PANEL CUTOUT SIZE | 80 x 68 mm |
| Certification | CE,ISO9001 |
| Parameter | Original | KAIYUE Replacement |
|---|---|---|
| Control type | AMF / MRS / Auto-Start | AMF mains-failure and remote start |
| DC supply | 12/24 VDC nominal | 12/24 VDC selectable; confirm battery system |
| AC sensing | 0–600 VAC, 1/3 phase | 0–600 VAC sensing; terminal map supplied |
| Output rating | Relay outputs, reference-dependent | Relay outputs sized for stated contactor/solenoid loads |
| Magnetic pickup input | 0.5–35 VAC, 10–10,000 Hz | 0.5–35 VAC compatible pickup input |
| Panel cut-out / dimensions | Reference drawing required | Proposed drawing confirmed before shipment |
| Weight / protection | Reference unit; IP rating by enclosure | Approx. 0.28 kg; front sealing option by project |
DSE3110 listings explicitly identified as MPU versions ranged from US$32.15 to US$198.00 per controller. Many replacement offers occupied the lower part of the range, while an original-supply claim set the upper endpoint. For panel-builder orders, compare the required speed input and terminal assignments first, then request supply documentation, configuration support and matched quantity prices. CAN-labelled modules and version-unspecified offers are excluded from this MPU benchmark.
Identify the installed model and compare terminal layout, functions and panel cut-out with the proposed replacement — confirm the specification with our team.
View this answer in FAQs ↗Some replacements are near drop-in while others require wiring and configuration changes. Confirm compatibility for the specific pair of models — confirm the specification with our team.
View this answer in FAQs ↗They are widely used for generator set control, including manual, automatic and AMF operation, with protection and monitoring functions — confirm the specification with our team.
View this answer in FAQs ↗Overcrank indicates the engine did not start within the configured crank attempts. Check fuel supply, starting system, speed sensing and crank timing settings.
View this answer in FAQs ↗Provide generator rating, engine type, required features, communication needs, panel space and photos of the existing installation. ---
View this answer in FAQs ↗