DSE6020 MKII
Deep Sea Controller Auto Start Control Module DSE6020 MKII for generator
Deep Sea Controller Auto Start Control Module DSE720 for generator
DSE720 Deep Sea legacy AMF controller.
| Warranty | 13 months |
|---|---|
| Place of Origin | Fujian, China |
| Brand Name | KAIYUE |
| Model Number | DSE720 |
| OVERALL SIZE | 209 x 146 x 30.3 mm |
| PANEL CUTOUT SIZE | 182 x 137 mm |
| Certification | CE,ISO9001 |
| Parameter | Original | KAIYUE Replacement |
|---|---|---|
| Control type | AMF / MRS / Auto-Start | Auto-Start with genset protection |
| DC supply | 12/24 VDC nominal | 12/24 VDC selectable; confirm battery system |
| AC sensing | 0–600 VAC, 1/3 phase | 0–600 VAC sensing; terminal map supplied |
| Output rating | Relay outputs, reference-dependent | Relay outputs sized for stated contactor/solenoid loads |
| Magnetic pickup input | 0.5–35 VAC, 10–10,000 Hz | 0.5–35 VAC compatible pickup input |
| Panel cut-out / dimensions | Reference drawing required | Proposed drawing confirmed before shipment |
| Weight / protection | Reference unit; IP rating by enclosure | Approx. 0.53 kg; front sealing option by project |
| Product Name | Deep Sea Controller Auto Start Control Module DSE720 for generator | |
| DC Supply | 8.0V to 35V Continuous. | |
| Cranking Dropouts | Able to survive 0V for 50mS, providing supply was at least 10V before dropout and supply recovers to 5V. This is achieved without the need for internal batteries. | |
| Typical Standby Current | 145mA at 12V. 150mA at 24V | |
| Max. Operating Current | 180mA at 12V. 190mA at 24V | |
| Alternator / Mains (Utility) Input Frequency | 50Hz - 60 Hz at rated engine speed | |
Listings for the DSE720 generator controller ranged from US$68.10 to US$128.80 per module. Several offers came in below the top of the range, so use the upper end only after checking what the quote covers. For service stock, compare the required start and protection functions and verify whether setup or testing is included.
Identify the installed model and compare terminal layout, functions and panel cut-out with the proposed replacement — confirm the specification with our team.
View this answer in FAQs ↗Some replacements are near drop-in while others require wiring and configuration changes. Confirm compatibility for the specific pair of models — confirm the specification with our team.
View this answer in FAQs ↗They are widely used for generator set control, including manual, automatic and AMF operation, with protection and monitoring functions — confirm the specification with our team.
View this answer in FAQs ↗Overcrank indicates the engine did not start within the configured crank attempts. Check fuel supply, starting system, speed sensing and crank timing settings.
View this answer in FAQs ↗Provide generator rating, engine type, required features, communication needs, panel space and photos of the existing installation. ---