KAIYUE KAIYUEGENERATOR PARTS
Get a Quote
Deep Sea Controller Series

DSE705

Deep Sea Controller Auto Start Control Module DSE705 for generator

DSE705 Deep Sea automatic transfer switch controller.

Model NumberDSE705
OVERALL SIZE165 x 125 x 29 mm
PANEL CUTOUT SIZE149 x 109 mm
Discuss on WhatsApp ↗

Technical Data

Warranty 13 months
Place of Origin Fujian, China
Brand Name KAIYUE
Model Number DSE705
OVERALL SIZE 165 x 125 x 29 mm
PANEL CUTOUT SIZE 149 x 109 mm
Certification CE,ISO9001
ParameterOriginalKAIYUE Replacement
Control typeAMF / MRS / Auto-StartAuto-Start with genset protection
DC supply12/24 VDC nominal12/24 VDC selectable; confirm battery system
AC sensing0–600 VAC, 1/3 phase0–600 VAC sensing; terminal map supplied
Output ratingRelay outputs, reference-dependentRelay outputs sized for stated contactor/solenoid loads
Magnetic pickup input0.5–35 VAC, 10–10,000 Hz0.5–35 VAC compatible pickup input
Panel cut-out / dimensionsReference drawing requiredProposed drawing confirmed before shipment
Weight / protectionReference unit; IP rating by enclosureApprox. 0.82 kg; front sealing option by project
Product Name Deep Sea Controller Auto Start Control Module DSE705 for generator
Output A (Fuel)MAINS (UTILITY) Voltage Range 15 V to 415 V AC (Ph to N)26 V to 719 V AC (Ph to Ph)
Frequency Range 3.5 Hz to 75 Hz
OUTPUTS Output A (Fuel) 10 A short term, 5 A continuous,at supply voltage
Output B (Start) 10 A short term, 5 A continuous,at supply voltage
Auxiliary Outputs C, D, E &F 2 A DC at supply voltage

DSE705 Introduction

The DSE705 is listed by Deep Sea as an automatic transfer control module.

Remote start, fault monitoring and changeover
Confirm the load-transfer circuit and breaker feedback the panel requires. Compare its rear terminals and fixing positions with the installed controller before placing the order.

Global Market Price Reference (USD)

Explicit DSE705 controller offers ranged from US$25.00 to US$118.68 per unit. The lowest one-piece trade advertisement sat below a substantial group of replacement quotations, while the upper matched offers were comparatively close to one another. This suggests buyers can seek competitive replacement supply without using unidentified high-priced controllers as a benchmark. For ATS-panel procurement, confirm the actual transfer logic, start interfaces, terminal layout and configuration service; generic 705 and P705-only listings were not included.

How do I find a direct replacement for an existing unit?

Identify the installed model and compare terminal layout, functions and panel cut-out with the proposed replacement — confirm the specification with our team.

View this answer in FAQs ↗
Can newer models replace older ones directly?

Some replacements are near drop-in while others require wiring and configuration changes. Confirm compatibility for the specific pair of models — confirm the specification with our team.

View this answer in FAQs ↗
What are Deep Sea controllers used for?

They are widely used for generator set control, including manual, automatic and AMF operation, with protection and monitoring functions — confirm the specification with our team.

View this answer in FAQs ↗
Why does the controller show an overcrank fault?

Overcrank indicates the engine did not start within the configured crank attempts. Check fuel supply, starting system, speed sensing and crank timing settings.

View this answer in FAQs ↗
What information helps select the right controller?

Provide generator rating, engine type, required features, communication needs, panel space and photos of the existing installation. ---

View this answer in FAQs ↗
Product image enlarged

KAIYUE / REQUEST A QUOTE

20 YEARS EXPERIENCE FOR GENSET PARTS


Email is required so we can reply to your inquiry.

en_US
en_US