DSE6010
Deep Sea Controller Auto Start Control Module DSE6010 for generator
Comap Controller Auto Mains Failure AMF Generator Controller AMF25
AMF25 ComAp single-genset AMF reference.
| Warranty | 13 months |
|---|---|
| Place of Origin | Fujian, China |
| Brand Name | KAIYUE |
| Model Number | AMF25 |
| OVERALL SIZE | 275 × 160 ×95 mm |
| Weight | 0.6kg |
| Certification | CE,ISO9001 |
| Parameter | Original | KAIYUE Replacement |
|---|---|---|
| Control type | AMF / MRS / Auto-Start | Auto-Start with genset protection |
| DC supply | 12/24 VDC nominal | 12/24 VDC selectable; confirm battery system |
| AC sensing | 0–600 VAC, 1/3 phase | 0–600 VAC sensing; terminal map supplied |
| Output rating | Relay outputs, reference-dependent | Relay outputs sized for stated contactor/solenoid loads |
| Magnetic pickup input | 0.5–35 VAC, 10–10,000 Hz | 0.5–35 VAC compatible pickup input |
| Panel cut-out / dimensions | Reference drawing required | Proposed drawing confirmed before shipment |
| Weight / protection | Reference unit; IP rating by enclosure | Approx. 0.64 kg; front sealing option by project |
For the InteliLite 4 AMF25 version, two matching market listings ranged from US$630.86 to US$739.94 per controller. This limited sample gives a more focused budget reference than mixing generations, but does not establish a wider market trend. For a panel retrofit, confirm that InteliLite 4 is the required generation and include harness, configuration and commissioning needs in the batch quotation. Gen2 AMF25 and AMF20 modules are separate price comparisons.
Replacement is often possible but requires wiring adaptation and new configuration. Review the input/output mapping before deciding — confirm the specification with our team.
View this answer in FAQs ↗Identify the current controller model and required functions such as AMF, paralleling or remote communication. Confirm the exact variant — confirm the specification with our team.
View this answer in FAQs ↗They are used for generator set control, monitoring and protection, including automatic mains failure and more advanced control applications. Feature sets differ by model — confirm the specification with our team.
View this answer in FAQs ↗Fault reset normally requires clearing the alarm on the panel after the cause has been corrected. Repeated faults should be investigated rather than reset repeatedly.
View this answer in FAQs ↗Send the existing controller model, generator set details, required functions, communication needs, panel cut-out dimensions and photos of the wiring terminals. ---
View this answer in FAQs ↗