DSE8610 MKII
Deep Sea Controller Auto Start Control Module DSE8610 MKII for generator
Comap Controller Manual Remote Start(MRS) Generator Controller MRS11
MRS11 ComAp InteliLite manual and remote start module.
| Warranty | 13 months |
|---|---|
| Place of Origin | Fujian, China |
| Brand Name | KAIYUE |
| Model Number | MRS11 |
| OVERALL SIZE | 245 x 184 x 51 mm |
| Weight | 0.9kg |
| Certification | CE,ISO9001 |
| Parameter | Original | KAIYUE Replacement |
|---|---|---|
| Control type | AMF / MRS / Auto-Start | MRS manual/remote start |
| DC supply | 12/24 VDC nominal | 12/24 VDC selectable; confirm battery system |
| AC sensing | 0–600 VAC, 1/3 phase | 0–600 VAC sensing; terminal map supplied |
| Output rating | Relay outputs, reference-dependent | Relay outputs sized for stated contactor/solenoid loads |
| Magnetic pickup input | 0.5–35 VAC, 10–10,000 Hz | 0.5–35 VAC compatible pickup input |
| Panel cut-out / dimensions | Reference drawing required | Proposed drawing confirmed before shipment |
| Weight / protection | Reference unit; IP rating by enclosure | Approx. 0.41 kg; front sealing option by project |
MRS11-reference controller listings ranged from US$195.17 to US$599.99 per module. The sample mixed replacement panels with ComAp-labelled offers and used different generation descriptions, including InteliLite NT and IL-MRS11, so the span is an initial sourcing reference rather than a verified interchangeable-parts band. For service contracts, confirm the exact label, engine interface, harness and configuration support before comparing batch quotations. MRS10 and ambiguous multi-model substitutes are excluded.
Replacement is often possible but requires wiring adaptation and new configuration. Review the input/output mapping before deciding — confirm the specification with our team.
View this answer in FAQs ↗Identify the current controller model and required functions such as AMF, paralleling or remote communication. Confirm the exact variant — confirm the specification with our team.
View this answer in FAQs ↗Remote monitoring capability depends on the model and optional communication modules. Confirm which options apply — confirm the specification with our team.
View this answer in FAQs ↗Fault reset normally requires clearing the alarm on the panel after the cause has been corrected. Repeated faults should be investigated rather than reset repeatedly.
View this answer in FAQs ↗Send the existing controller model, generator set details, required functions, communication needs, panel cut-out dimensions and photos of the wiring terminals. ---
View this answer in FAQs ↗