DSE7320 MKII
Deep Sea Controller Auto Start Control Module DSE7320 MKII for generator
SmartGen Controller Auto Start Generator Controller HGM9520
HGM9520 SmartGen synchronising controller.
| Warranty | 13 months |
|---|---|
| Place of Origin | Fujian, China |
| Brand Name | KAIYUE |
| Model Number | HGM9520 |
| Weight | 3kg |
| Certification | CE,ISO9001 |
| Parameter | Original | KAIYUE Replacement |
|---|---|---|
| Control type | AMF / MRS / Auto-Start | Auto-Start with genset protection |
| DC supply | 12/24 VDC nominal | 12/24 VDC selectable; confirm battery system |
| AC sensing | 0–600 VAC, 1/3 phase | 0–600 VAC sensing; terminal map supplied |
| Output rating | Relay outputs, reference-dependent | Relay outputs sized for stated contactor/solenoid loads |
| Magnetic pickup input | 0.5–35 VAC, 10–10,000 Hz | 0.5–35 VAC compatible pickup input |
| Panel cut-out / dimensions | Reference drawing required | Proposed drawing confirmed before shipment |
| Weight / protection | Reference unit; IP rating by enclosure | Approx. 0.63 kg; front sealing option by project |
Confirmed HGM9520 controller offers ranged from US$1,178.00 to US$1,499.23 per unit. The comparable quotations formed a relatively contained band for this parallel-control model; an apparently much cheaper search card resolved to a different controller configuration and was excluded. For project procurement, compare the exact HGM9520 hardware, firmware, synchronising and breaker-control requirements, together with commissioning support. Mixed HGM9510/HGM9520 options and pack totals are not a basis for unit-price comparison.
Replacement is common but requires terminal mapping and reconfiguration. Confirm input/output compatibility — confirm the specification with our team.
View this answer in FAQs ↗Compare measurement capability, protection functions, AMF support, communication interfaces and display options against your requirement — confirm the specification with our team.
View this answer in FAQs ↗They provide generator control, protection and monitoring for standby, prime and AMF applications, with model-dependent features — confirm the specification with our team.
View this answer in FAQs ↗Speed signal loss usually points to a faulty magnetic pickup, incorrect sensor gap, wiring break or configuration mismatch. Inspect the sensor installation.
View this answer in FAQs ↗Include the controller model, generator rating, engine type, required functions, panel dimensions, quantity and photos. ---
View this answer in FAQs ↗