DSE8610 MKII
Deep Sea Controller Auto Start Control Module DSE8610 MKII for generator
Comap Controller Auto Mains Failure AMF Generator Controller AMF9
AMF9 ComAp InteliLite NT AMF controller.
| Warranty | 13 months |
|---|---|
| Place of Origin | Fujian, China |
| Brand Name | KAIYUE |
| Model Number | AMF9 |
| OVERALL SIZE | 275 × 160 × 95 mm |
| Weight | 1kg |
| Certification | CE,ISO9001 |
| Parameter | Original | KAIYUE Replacement |
|---|---|---|
| Control type | AMF / MRS / Auto-Start | Auto-Start with genset protection |
| DC supply | 12/24 VDC nominal | 12/24 VDC selectable; confirm battery system |
| AC sensing | 0–600 VAC, 1/3 phase | 0–600 VAC sensing; terminal map supplied |
| Output rating | Relay outputs, reference-dependent | Relay outputs sized for stated contactor/solenoid loads |
| Magnetic pickup input | 0.5–35 VAC, 10–10,000 Hz | 0.5–35 VAC compatible pickup input |
| Panel cut-out / dimensions | Reference drawing required | Proposed drawing confirmed before shipment |
| Weight / protection | Reference unit; IP rating by enclosure | Approx. 0.52 kg; front sealing option by project |
Clearly identified InteliLite 4 AMF9 / IL4AMF9 offers ranged from US$250.00 to US$519.90 per controller. The lower quotations were advertised for single-piece wholesale supply, while another module listing asked substantially more, suggesting room to compare trade-sourcing terms. For panel orders, request the full IL4AMF9 product code, supply-origin evidence and configuration support before negotiating quantity pricing. AMF8, AMF20 and adverts with uncertain model identification are excluded.
Replacement is often possible but requires wiring adaptation and new configuration. Review the input/output mapping before deciding — confirm the specification with our team.
View this answer in FAQs ↗Identify the current controller model and required functions such as AMF, paralleling or remote communication. Confirm the exact variant — confirm the specification with our team.
View this answer in FAQs ↗They are used for generator set control, monitoring and protection, including automatic mains failure and more advanced control applications. Feature sets differ by model — confirm the specification with our team.
View this answer in FAQs ↗Fault reset normally requires clearing the alarm on the panel after the cause has been corrected. Repeated faults should be investigated rather than reset repeatedly.
View this answer in FAQs ↗Send the existing controller model, generator set details, required functions, communication needs, panel cut-out dimensions and photos of the wiring terminals. ---
View this answer in FAQs ↗