DSE701
Deep Sea Controller Manual & Auto Start Control Module DSE701 for generator
Deep Sea Controller Auto Start Control Module DSE5220 for generator
DSE5220 Deep Sea AMF module.
| Warranty | 13 months |
|---|---|
| Place of Origin | Fujian, China |
| Brand Name | KAIYUE |
| Model Number | DSE5220 |
| OVERALL SIZE | 240 x 172 mm |
| PANEL CUTOUT SIZE | 220 x 160 mm |
| Certification | CE,ISO9001 |
| Parameter | Original | KAIYUE Replacement |
|---|---|---|
| Control type | AMF / MRS / Auto-Start | AMF mains-failure and remote start |
| DC supply | 12/24 VDC nominal | 12/24 VDC selectable; confirm battery system |
| AC sensing | 0–600 VAC, 1/3 phase | 0–600 VAC sensing; terminal map supplied |
| Output rating | Relay outputs, reference-dependent | Relay outputs sized for stated contactor/solenoid loads |
| Magnetic pickup input | 0.5–35 VAC, 10–10,000 Hz | 0.5–35 VAC compatible pickup input |
| Panel cut-out / dimensions | Reference drawing required | Proposed drawing confirmed before shipment |
| Weight / protection | Reference unit; IP rating by enclosure | Approx. 0.28 kg; front sealing option by project |
DSE5220 controller offers ranged from US$128.00 to US$973.08 per unit or single set, excluding pre-owned stock. Many replacement quotations were closely grouped toward the lower end, whereas advertised genuine options and higher industrial-supply quotations formed a distinct premium tier. For AMF-panel procurement, compare documented origin, utility sensing, terminal assignments, firmware and configuration support before paying that premium. DSE5120 selections, 5210 options and mixed-model advertisements were excluded.
Identify the installed model and compare terminal layout, functions and panel cut-out with the proposed replacement — confirm the specification with our team.
View this answer in FAQs ↗Some replacements are near drop-in while others require wiring and configuration changes. Confirm compatibility for the specific pair of models — confirm the specification with our team.
View this answer in FAQs ↗They are widely used for generator set control, including manual, automatic and AMF operation, with protection and monitoring functions — confirm the specification with our team.
View this answer in FAQs ↗Overcrank indicates the engine did not start within the configured crank attempts. Check fuel supply, starting system, speed sensing and crank timing settings.
View this answer in FAQs ↗Provide generator rating, engine type, required features, communication needs, panel space and photos of the existing installation. ---
View this answer in FAQs ↗