DSE7220
Deep Sea Controller Auto Start Control Module DSE7220 for generator
Deep Sea Controller Auto Start Control Module DSE4520 MKII for generator
DSE4520 MKII Deep Sea AMF controller for standby transfer panels.
| Warranty | 13 months |
|---|---|
| Place of Origin | Fujian, China |
| Brand Name | KAIYUE |
| Model Number | DSE4520 MKII |
| OVERALL SIZE | 140 x 113x 43 mm |
| PANEL CUTOUT SIZE | 118 x 92 mm |
| Certification | CE,ISO9001 |
| Parameter | DSE4520 MKII (Original) | KAIYUE Replacement |
|---|---|---|
| Control Duty | AMF / Auto-Start | AMF / Auto-Start |
| DC Supply Voltage | 8–35 V DC | 8–35 V DC |
| Mains Voltage Range (Ph-N) | 15–415 V AC | 15–415 V AC |
| Frequency Range | 3.5–75 Hz | 3.5–75 Hz |
| Output A (Fuel) | 10 A short / 5 A cont. | 10 A short / 5 A cont. |
| Output B (Start) | 10 A short / 5 A cont. | 10 A short / 5 A cont. |
| Magnetic Pick-up Input | ±0.5–70 V | ±0.5–70 V |
| Panel Cutout (W x H) | 118 x 92 mm | 118 x 92 mm |
| Overall Size (W x H x D) | 140 x 113 x 43 mm | 140 x 113 x 43 mm |
| Weight | 0.26 kg | 0.26 kg |
| Operating Temperature | -30 to +70 C | -30 to +70 C |
| Ingress Protection | IP65 (front panel) | IP65 (front panel) |
| Variant Code | Control Mode | Display | Communication |
|---|---|---|---|
| DSE4520-05 | AMF (Mains Failure) | LCD | RS-232 / USB |
| DSE4520 Auto-Start | Auto-Start only | LCD | RS-232 / USB |
| Product Name | Deep Sea Controller Auto Start Control Module DSE4520 MKII for generator | |
| MAINS (UTILITY) | VOLTAGE RANGE | 15 V to 415 V AC (Ph to N)26 V to 719 V AC (Ph to Ph) |
| FREQUENCY RANGE | 3.5 Hz to 75 Hz | |
| OUTPUTS | OUTPUT A (FUEL) | 10 A short term, 5 A continuous, at supply voltage |
| OUTPUT B (START) | 10 A short term, 5 A continuous,at supply voltage | |
| MAGNETIC PICK-UP | +/- 0.5 V to 70 V | |
DSE4520 MKII replacement modules were offered at US$54.87–141.50 per unit. The wide spread gives panel builders room to negotiate on repeat orders. Compare the same MKII revision and verify which terminal plugs and configuration support the quote includes.
Identify the installed model and compare terminal layout, functions and panel cut-out with the proposed replacement — confirm the specification with our team.
View this answer in FAQs ↗Some replacements are near drop-in while others require wiring and configuration changes. Confirm compatibility for the specific pair of models — confirm the specification with our team.
View this answer in FAQs ↗They are widely used for generator set control, including manual, automatic and AMF operation, with protection and monitoring functions — confirm the specification with our team.
View this answer in FAQs ↗Overcrank indicates the engine did not start within the configured crank attempts. Check fuel supply, starting system, speed sensing and crank timing settings.
View this answer in FAQs ↗Provide generator rating, engine type, required features, communication needs, panel space and photos of the existing installation. ---
View this answer in FAQs ↗