DSE6120
Deep Sea Controller Auto Start Control Module DSE6120 for generator
Deep Sea Controller Auto Start Control Module DSE8610 MKII for generator
DSE8610 MKII Deep Sea controller for genset synchronising and load sharing.
| Warranty | 13 months |
|---|---|
| Place of Origin | Fujian, China |
| Brand Name | KAIYUE |
| Model Number | DSE8610 MKII |
| OVERALL SIZE | 245 mm x 184 mm x 51 mm (9.6" x 7.2" x 2.0") |
| PANEL CUTOUT SIZE | 220 mm x 160 mm (8.7" x 6.3") |
| Certification | CE,ISO9001 |
| Parameter | Original | KAIYUE Replacement |
|---|---|---|
| Control type | AMF / MRS / Auto-Start | AMF mains-failure and remote start |
| DC supply | 12/24 VDC nominal | 12/24 VDC selectable; confirm battery system |
| AC sensing | 0–600 VAC, 1/3 phase | 0–600 VAC sensing; terminal map supplied |
| Output rating | Relay outputs, reference-dependent | Relay outputs sized for stated contactor/solenoid loads |
| Magnetic pickup input | 0.5–35 VAC, 10–10,000 Hz | 0.5–35 VAC compatible pickup input |
| Panel cut-out / dimensions | Reference drawing required | Proposed drawing confirmed before shipment |
| Weight / protection | Reference unit; IP rating by enclosure | Approx. 0.66 kg; front sealing option by project |
| CONTINUOUS VOLTAGE RATING | 8 V to 35 V Continuous | |
| GENERATOR | VOLTAGE RANGE | 15 V - 333 V AC (L-N) |
| FREQUENCY RANGE | 3.5 Hz to 75 Hz | |
| OUTPUTS | OUTPUT A (FUEL) | 15 A DC at supply voltage |
| OUTPUT B (START) | 15 A DC at supply voltage | |
| AUXILIARY OUTPUTS E,F,G,H,I & J | 2 A DC at supply voltage | |
DSE8610 MKII controller offers ranged from US$749.00 to US$6,000.00 per unit. Notably, the lowest listing claimed original supply while several replacement-labelled offers cost more, so neither price nor an advert's wording verifies authenticity. For synchronising and load-sharing projects, request traceable supply documentation, the exact module code and compatible configuration software, then compare commissioning support and batch pricing. Used modules, parts-only units and control-box harness assemblies are excluded.
Identify the installed model and compare terminal layout, functions and panel cut-out with the proposed replacement — confirm the specification with our team.
View this answer in FAQs ↗Some replacements are near drop-in while others require wiring and configuration changes. Confirm compatibility for the specific pair of models — confirm the specification with our team.
View this answer in FAQs ↗They are widely used for generator set control, including manual, automatic and AMF operation, with protection and monitoring functions — confirm the specification with our team.
View this answer in FAQs ↗Overcrank indicates the engine did not start within the configured crank attempts. Check fuel supply, starting system, speed sensing and crank timing settings.
View this answer in FAQs ↗Provide generator rating, engine type, required features, communication needs, panel space and photos of the existing installation. ---
View this answer in FAQs ↗